Hi,
I was testing the newish HTTP Server component located in fcl-web/src/fphttpserver.pp
I simply created a form with Start/Stop button. The problem is, that once I call .Active := True, it never returns from that call, so my test program (and thus any program using this server component) is stuck in limbo land...
Is this a known problem? And more importantly, is there a work-around? I'm using FPC 2.5.1 (the latest revision in the 2.6.0 fixes branch).
procedure TMainForm.ButtonClicked(Sender: TObject);
begin
if Button1.Text = 'Start' then
begin
writeln('before start');
FHTTPServer.Active := True;
writeln('after start');
Button1.Text := 'Stop';
end
else
begin
writeln('before stop');
FHTTPServer.Active := False;
writeln('after stop');
Button1.Text := 'Start';
end;
end;Note:
Once the HTTP Server is running, it does correctly handle and respond to HTTP requests, so the worker thread of the http server is working. It is just that the program implementing the HTTP Server component is frozen, and its process has to be killed to terminate the http server.