Hello Armin,
Tuesday, September 03, 2002, 9:59:21 AM, you wrote:
AR> I Have write the function (using ppc386 on WIN2000 System):
AR> function GetMessData: integer;
AR> type
AR> pak = record
AR> werte : String[23];
AR> end;
AR> PakFile = file of pak;
AR> var
AR> i : integer;
AR> F : PakFile;
AR> begin
AR> Assign(F,'C:\Temp\amag.txt');
AR> Reset(F);
AR> end;
AR> In the moment, there are not more line in the code of this function. AR> compiling is ok.
AR> but the linker send the error:
AR> -:link.res: file format not recognized; treating as linker script AR> -:link.res:1: parse error
AR> unwucht.pp(165,1) ERROR: ERROR while linking
AR> Closing script ppas.bat
AR> Please include the link.res also
AR> --------------
AR> here link.res
AR> SEARCH_DIR(g:\pc\pp\unwucht\VERSI~L!\)
AR> SEARCH_DIR(g:\pc\pp\units\win32\)
AR> SEARCH_DIR(g:\pc\pp\units\win32\rtl\)
AR> INPUT(
AR> g:\pc\pp\units\win32\rtl\wprt0.ow
AR> g:\pc\pp\unwucht\VERSI~L!\unwucht.ow
AR> )
AR> GROUP(
AR> g:\pc\pp\units\win32\rtl\libpdos.aw
AR> g:\pc\pp\units\win32\rtl\LIBPW~JH.AW
AR> g:\pc\pp\units\win32\rtl\LIBPS~GM.AW
AR> g:\pc\pp\units\win32\rtl\LIBPO~14.AW
AR> g:\pc\pp\units\win32\rtl\LIBPS~UD.AW
AR> )
Are you sure that your linker is ldw for Win32?
ld's for different targets can have different script formats. 1) Try to compile and link separately (read -s compiler switch documentation); 2) Check targets supported by linker.
Best regards,
Pavel